7
7.2 Parameter List
436
08501 Function setting
PRM
8508, 8509
08504 Switch setting
#0 HE1 : The first high–speed position switch is,
enabled (0)/disabled (1)
#1 HE2 : The second high–speed position switch is,
enabled (0)/disabled (1)
#2 HE3 : The third high–speed position switch is,
enabled (0)/disabled (1)
#3 HE4 : The fourth high–speed position switch is,
enabled (0)/disabled (1)
#4 HE5 : The fifth high–speed position switch is,
enabled (0)/disabled (1)
#5 HE6 : The sixth high–speed position switch is,
enabled (0)/disabled (1)
#6 HE7 : The seventh high–speed position switch is,
enabled (0)/disabled (1)
#7 HE8 : The eighth high–speed position switch is,
enabled (0)/disabled (1)
08505 Switch setting
#0 HE9 : The ninth high–speed position switch is,
enabled (0)/disabled (1)
#1 HEA : The tenth high–speed position switch is,
enabled (0)/disabled (1)
#2 HEB : The eleventh high–speed position switch is,
enabled (0)/disabled (1)
#3 HEC : The twelfth high–speed position switch is,
enabled (0)/disabled (1)
#4 HED : The thirteenth high–speed position switch is,
enabled (0)/disabled (1)
#5 HEE : The fourteenth high–speed position switch is,
enabled (0)/disabled (1)
#6 HEF : The fifteenth high–speed position switch is,
enabled (0)/disabled (1)
#7 HEG : The sixteenth high–speed position switch is,
enabled (0)/disabled (1)
#0 HPO : The output signal of a high–speed position
switch is output to, address Y. (PRM8565)
(0)/address F. <
IF2345+
or
IF2353+
> (1)
#1 HPE : The current position used with the high–speed
position switch of decision–by–direction type,
considers a servo error (0)/does not consider
a servo error (1)