13
13.2 Diagnosis Information (DGN) List
782
THL, THH:
THL
THH Status
0 0 A battery alarm has occurred in the PANEL i or CNC dis-
play unit with PC functions.
1 0 A high–temperature condition has occurred in the PAN-
EL i or CNC display unit with PC functions.
0 1 A low–temperature condition has occurred in the PAN-
EL i or CNC display unit with PC functions.
1 1 Normal (connected to the PC)
#4: 0: Normal
1: An NMI has occurred in HSSB.
#7
#6 #5 #4 #3 #2 #1 #0
513DGN
Indicates the internal information about the HSSB (open CNC). (Hidden
function)
#7
#6 #5 #4 #3 #2 #1 #0
515DGN
Indicates the internal information about the HSSB (channel 2). (Hidden
function)
#7
#6 #5 #4 #3 #2 #1 #0
516DGN
Indicates the internal information about the HSSB (channel 2). (Hidden
function)
#7
#6 #5 #4 #3 #2 #1 #0
517DGN
THH THL PRA
Indicates the internal information about the HSSB (channel 2) as follows.
PRA: 0: Normal
1: A RAM parity error has occurred in shared RAM.
THL, THH:
THL
THH Status
0 0 A battery alarm has occurred in the PANEL i or CNC dis-
play unit with PC functions.
1 0 A high–temperature condition has occurred in the PAN-
EL i or CNC display unit with PC functions.
0 1 A low–temperature condition has occurred in the PAN-
EL i or CNC display unit with PC functions.
1 1 Normal (connected to the PC)
#4: 0: Normal
1: An NMI has occurred in the HSSB.
#7
#6 #5 #4 #3 #2 #1 #0
518DGN
Indicates the internal information about the HSSB (channel 2). (Hidden
function)