10. PMC
635
10.1.1.4 Net editing screen
On the net editing screen, net editing operations such as the creation of a
new net and the modification of an existing net can be performed.
D Modification to an existing net
If the net editing screen is displayed with the [MODIFY] soft key, the
mode (modification mode) for modifying the net indicated by the
cursor is set.
D Addition of a new net
If the net editing screen is displayed with the [CREATE] soft key, the
mode (creation mode) for creating a new net from a free state is set.
(1) Display method
<1> Display the ladder diagram editing screen.
<2> Press the [ADD] or [MODIFY] soft key.
(2) Display information
Editing mode
Additional information line
Net number being edited
Display subprogram
Message display line
Key input line
Cursor
Ladder diagram display area
(3) Editing nets
By using the keys indicated below, a new net can be created, and an
existing net can be modified.
D Placing a new contact or coil
<1> Move the cursor to the position where a new contact or coil is
to be placed.
<2> Enter a bit address, then press a soft key such as [
],
[
].
D Changing the type of a contact or coil
<1> Move the cursor to the position where the type of a contact or
coil is to be changed.
<2> Press a soft key such as [
], [ ].
D Changing the address of a contact or coil
<1> Move the cursor to a relay to be modified.
<2> Enter a bit address, then press the ENTER key.
D Placing a new function instruction
<1> Move the cursor to the position where a new function
instruction is to be placed.
<2> Enter a function instruction number, then press the [FUNC]
soft key.