7. PARAMETERS
297
02024 No. of position pulses <Axis>
PRM
2000#0,
2185
See
Chapter 16
1 Position detecting by built-in type of pulse coder
2 In case of separate type of position detector, Setting
value=the feedback pulse/motor one revolution 4
When bit 0 of parameter No. 2000 is 1, use the value
obtained by dividing, by 10, the value used when this bit is 0.
12500
Serial PC /a PC
PRM
2000#0=0
PRM
2000#0=1
1250
02028 Speed at which the position gain is switched <Axis>
PRM
2015#0
02029 Acceleration–time velocity enabling integration
function for low speed.
<Axis>
PRM
02030 Deceleration–time velocity enabling integration
function for low speed
2015#1
02033 Number of position feedback pulses <Axis>
02034 Vibration–damping control gain <Axis>
02039 Second–stage acceleration of the two–stage
backlash acceleration function
<Axis>
02040 Current loop integral gain (PK1) <Axis>
Need not
changed
02041 Current loop proportional gain (PK2) <Axis>
02042 Current loop gain (PK3) <Axis>
Need not
changed
02043 Velocity loop integral gain (PK1V) <Axis>
Need not
changed
02044 Velocity loop proportional gain (PK2V) <Axis>
02045 Velocity loop incomplete integral gain (PK3V) <Axis>
02046 Velocity loop gain (PK4V) <Axis>
Need not
changed
02047 Observer parameter (POA1) <Axis>
Need not
changed