13. DIAGNOSIS INFORMATION
767
DUA 0: The slave of interest is not on the first axis of the two–axis
amplifier.
1: The slave of interest is on the first axis of the two–axis amplifier.
EXT 0: The slave of interest does not exist.
1: The slave of interest exists.
#7
#6 #5 #4 #3 #2 #1 #0
331DGN
DMA TP1 TP0 HA2 HA1 HA0
#7
#6 #5 #4 #3 #2 #1 #0
333DGN
DMA TP1 TP0 HA2 HA1 HA0
to
349DGN
DMA TP1 TP0 HA2 HA1 HA0
HA0, HA1, HA2 : Indicates the host LSI address specified as a DMA
destination.
TP0, TP1 : Indicates the type code of a specified slave.
See ST0 and ST1 of the previously mentioned DGN330
and up.
DMA : Indicates a value determining whether to allow DMA to
occur.
NOTE A combination of DGN330 and 331 corresponds to one FSSB slave
unit. Up to ten slave units are available.
Slave units and the associated diagnosis numbers
Slave unit 00
Slave unit 01
Slave unit 02
Slave unit 03
Slave unit 04
Slave unit 05
Slave unit 06
Slave unit 07
Slave unit 08
Slave unit 09
³
³
³
³
³
³
³
³
³
³
DGN330, 331
DGN332, 333
DGN334, 335
DGN336, 337
DGN338, 339
DGN340, 341
DGN342, 343
DGN344, 345
DGN346, 347
DGN348, 349