7
7.2 Parameter List
288
01819 Follow-up, feed-forward, linear scale with
absolute address reference mark
<Axis>
#0 FUP : When the servo system is turned off, a
follow-up operation is performed based on
*FLWU (0)/is not performed (1).
#1 CRF : When servo alarm ALM445 (software
disconnection), ALM446 (hardware
disconnection), ALM447 (hardware
disconnection (separate type)), or ALM421
(excessive dual position feedback error) is
issued, the reference position setting remains
as is (0)/the system enters the reference
position undefined state (1)
#2 DAT : On a linear scale with absolute addressing
reference marks, the automatic setting of
PRM1883, 1884 is, not performed (0)/
performed (1)
(This parameter is automatically set to 0 when
the manualreference position return is
completed.)
#7 NAH : In advanced preview control mode, the
advance feed-forward function is used (0)/not
used (1).
M series
01820 Command multiply for each axis (CMR)
CMR =
CMR t 1 Setting value = (1/CMR) +100
CMR y 1 Setting value = 2 CMR
Least command increment
Detection unit
<Axis>
01821 Reference counter capacity for each axis
[Detection unit]
<Axis>
01825 Servo loop gain for each axis [0.01 sec
–1
] <Axis>
Std=3000
01826 Inposition width for each axis [Detection unit] <Axis>
01827 Inposition width for successive cutting feed
blocks for each axis [Detection unit]
<Axis>
PRM
1801#4
01828 Positioning deviation limit for each axis in
movement [Detection unit]
Setting value =
Rapid traverse
60 PRM1825
1
Detecting unit
1.2
<Axis>
PRM1420
PRM1825
01829 Positioning deviation limit for each axis in the
stopped state [Detection unit]
<Axis>
01830 Axis–by–axis positional deviation limit at
servo–off time [Detection unit]
<Axis>
PRM1829
01832 Feed stop positioning deviation for each axis
[Detection unit]
<Axis>