19
19.5 Maintenance of Open CNC (Boot–up and IPL)
950
19.5.4.3 Status screen (160is/180is/210is)
The status screen appears when the system tray icon is double–clicked or
NCBOOTis is restarted. This screen can be used to change the list of files
to save, restore, or start as well as to check the execution result.
To close the screen, press the [Close] button.
[About...] When this button is pressed, the version information screen
appears.
[CNC & keyboard type] This list is used to select the type of the CNC.
[List] This list is used to select the type of registered data to display or edit.
[Save] is used to select the files to be saved during power–down. [Load] is
used to select the files to be restored during power–up. [Start] is used to
select the files to be started during power–up.
[Insert] This button is used to newly register data.
[Delete] This button is used to delete the registered data from the selected
line.
[Up] This button is used to push forward the registration place of the selected
line.
[Down] This button is used to push back the registration place of the selected
line.
[Save] This button is used to save the registered files to the “\Storage
Card\Backup” folder. When automatic backup failed, restoration is
performed with the files.
[Clock] This button is used to adjust the calendar and clock. It also sets the
time difference (time zone) from Universal Coordinated Time.
[Screen saver enable] When this check box is checked, the screen saver is
enabled.
[Auto start NCBOOTis] When this check box is checked, NCBOOTis
automatically starts the next time.
[Backup unit Enable] When this check box is checked, the registry and files
are automatically saved during power–down. After power–down, the special
battery is used to supply the power during saving.
[High Priority] This check box is used to set the priority of automatic backup
task. To save some files with an application, uncheck this check box.