12. POWER MATE CNC MANAGER (FANUC SERVO
MOTOR AMPLIFIER β SERIES (I/O LINK OPTION))
753
With the Power Mate CNC Manager, position display and maintenance
operation (such as parameter setting) can be performed for the FANUC
SERVO MOTOR Amplifier β Series (I/O Link Option) (hereinafter referred to
as the “I/O Link β amplifier”).
12.1 Screen
(1) Screen display
1 Function key [SYSTEM]
2 Continuous menu key
(Press this key several times until the
[PMM] soft key appears.)
3 Soft key [PMM]
(Example of screen) System configuration screen
SYSTEM
SELECT ACTIVE SLAVE[>]
POWER MATE CNC MANAGER
SYSTEM CONFIGURATION
POS
[][][][][]
MSG
Message
line
1. GROUP1/ β
SYSTEM (SERIES/VERSION) 88A1 01
(2) Display information
D Position display
D System configuration screen
(I/O Link β amplifier system software information)
D Parameter screen
(setting and saving of I/O Link β amplifier parameters)
D Diagnosis screen (I/O Link β amplifier state)
D Alarm screen (I/O Link β amplifier alarm)
I/O Link β amplifier parameters
D Parameters can be read as a CNC program from an I/O Link β
amplifier (The read parameters are saved in the part program
storage memory or memory card on the CNC.)
D A parameter data file saved on the CNC can be written to the
corresponding I/O Link β amplifier. This relationship is determined
according to the connection of an I/O Link β amplifier and program
number.
See the descriptions of PRM960#2, #1, and PRM8760.
Message line
D An alarm or guidance message from the Power Mate CNC
Manager is displayed.
D If an alarm is issued from an I/O Link β amplifier, the group number
of the slave where the alarm is issued is indicated at the right end
of the message line. Details of the alarm can be checked on the
alarm screen.