19. MAINTENANCE FUNCTION
897
19.1.4 ALL IO screen (data input/output in a batch)
Programs, parameters, offset data, and macro variables can all be input and
output using a single common screen, that is, the ALL IO screen.
PRGRM
[][][][][]
PARAM OFFSET MACRO (OPRT)
READ/PUNCH (PROGRAM) O1234 N12345
I/O CHANNEL 3 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON BAUDRATE CLK. INNER
CD CHECK (232C) OFF RESET/ALARM ON
PARITY BIT OFF SAT COMMAND HOST
INTERFACE RS422 COM PROTCOL A
END CODE EXT COM CODE ASCII
(0:EIA 1:ISO)>1_
MDI * * * * * * * * * * * * * 12:34:56
ALL IO screen (example when I/O channel 3 is used)
19.1.4.1 Setting input/output–related parameters
Input/output–related parameters can be set on the ALL IO screen.
Parameters can be set, regardless of the mode.
D Procedure
1 Press function key
SYSTEM
.
2 Press the rightmost soft key
(continuous menu key) several
times.
3 Press soft key [ALL IO] to display the ALL IO screen.
PRGRM
[][][][][]
PARAM OFFSET MACRO (OPRT)
READ/PUNCH (PROGRAM) O1234 N12345
I/O CHANNEL 3 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON BAUDRATE CLK. INNER
CD CHECK (232C) OFF RESET/ALARM ON
PARITY BIT OFF SAT COMMAND HOST
INTERFACE RS422 COM PROTCOL A
END CODE EXT COM CODE ASCII
(0:EIA 1:ISO)>1_
MDI * * * * * * * * * * * * * 12:34:56
4 Select the soft key corresponding to the desired type of data (program,
parameter, and so forth).
5 Set the parameters corresponding to the type of input/output unit to be
used. (Parameter setting is possible regardless of the mode.)
Tip
First, set an I/O channel. The parameters on this screen change to those