17. AC SPINDLE
853
17.3 Automatic Setting of Standard Parameters
The standard parameters related to each serial spindle motor model can be
set automatically.
D The specifications for controlling a motor depend on the specifications
defined by the machine tool builder. The parameters defined by the
machine tool builder are set as the standard values (initial values) by
this automatic setting function.
Therefore, when performing automatic operation, always set
parameters properly according to the parameter list (parameters 4000
and later).
1. Turn on the power in the emergency stop state.
2. Set PRM4019#7 to 1.
#7
#6 #5 #4 #3 #2 #1 #0
4019
LDSP
LDSP The parameters for the serial interface spindle are:
0 : Not set automatically.
l 1 : Set automatically.
3. Set a motor model code to the PRM4133.
4133
Motor model code
4. Turn off the power then back on. Then, the parameters are read.
(Reference 1: Example of αi series motor model code)
Code Motor model Amplifier
302 a1/10000i SPM–2.2i
304 a1.5/10000i SPM–5.5i
306 a2/10000i SPM–5.5i
307 a2/15000i SPM–22i
308 a3/10000i SPM–5.5i
312 a8/8000i SPM–11i
314 a12/7000i SPM–15i
316 a15/7000i SPM–22i
320 a22/7000i SPM–26i
322 a30/6000i SPM–45i
323 a40/6000i SPM–45i
401 a6/12000i SPM–11i
406 a22/10000i SPM–26i
411 aP30/6000i SPM–22i
413 aP50/6000i SPM–26i