8
8.1 Alarms Displayed on NC Screen
500
No. ContentsMessage
433 n AXIS : CNV. LOW VOLT
DC LINK
1) PSM: The DC link voltage has
dropped.
2) PSMR: The DC link voltage has
dropped.
3) α series SVU: The DC link voltage has
dropped.
4) β series SVU: The DC link voltage has
dropped.
434 n AXIS : INV. LOW VOLT
CONTROL
SVM: The control power supply voltage
has dropped.
435 n AXIS : INV. LOW VOLT DC
LINK
SVM: The DC link voltage has dropped.
436 n AXIS : SOFTTHERMAL
(OVC)
The digital servo software detected the soft
thermal state (OVC).
437 n AXIS : CNV.
OVERCURRENT POWER
PSM: Overcurrent flowed into the input cir-
cuit.
438 n AXIS : INV. ABNORMAL
CURRENT
1) SVM: The motor current is too high.
2) α series SVU: The motor current is too
high.
3) β series SVU: The motor current is too
high.
439 n AXIS : CNV. OVERVOLT
POWER
1) PSM: The DC link voltage is too high.
2) PSMR: The DC link voltage is too high.
3) α series SVU: The C link voltage is too
high.
4) β series SVU: The link voltage is too
high.
440 n AXIS : CNV. EX
DECELERATION POW.
1) PSMR: The regenerative discharge
amount is too large.
2) α series SVU: The regenerative dis-
charge amount is too large. Alterna-
tively, the regenerative discharge cir-
cuit is abnormal.
441 n AXIS : ABNORMAL
CURRENT OFFSET
The digital servo software detected an ab-
normality in the motor current detection cir-
cuit.
442 n AXIS : CNV. CHARGE
FAILURE
1) PSM: The spare discharge circuit of
the DC link is abnormal.
2) PSMR: The spare discharge circuit of
the DC link is abnormal.
443 n AXIS : CNV. COOLING
FAN FAILURE
1) PSM: The internal stirring fan failed.
2) PSMR: The internal stirring fan failed.
3) β series SVU: The internal stirring fan
failed.
444 n AXIS : INV. COOLING FAN
FAILURE
SVM: The internal stirring fan failed.
445 n AXIS : SOFT
DISCONNECT ALARM
The digital servo software detected a bro-
ken wire in the pulse coder.
446 n AXIS : HARD
DISCONNECT ALARM
A broken wire in the built–in pulse coder
was detected by hardware.
447 n AXIS : HARD
DISCONNECT (EXT)
A broken wire in the separate detector was
detected by hardware.
448 n AXIS : UNMATCHED
FEEDBACK ALARM
The sign of feedback data from the built–in
pulse coder differs from that of feedback
data from the separate detector.