11
11.5 Ethernet Option Board
744
Err boot_mmc() [xxxxx]
An attempt to initialize the DNC1/Ethernet function or FOCA1/Ethernet
function failed. Replace the system with a CNC system or PMC system
that supports the DNC1/Ethernet function or FOCA1/Ethernet function.
(2) FAST_ETH FOCAS1 #0 LOG screen
This log screen is used to display an error message of the FOCAS1/Ethernet
function (DNC1/Ethernet function).
ALL TASKS(Cxx) ARE BUSY
All tasks have been activated.
The number of sockets that are connectable with the DNC1/Ethernet
function or FOCA1/Ethernet function was exceeded. Terminate
unnecessary applications, then reexecute the service.
(3) FAST_ETH FACTOLINK LOG screen
This log screen is used to display an error message of the FACTOLINK
function.
FACTOLINK#? IS TERMINATED
The parameters are in error. Cancel the services currently active on this
port. Check the set values of the own IP address, subnet mask, router
IP address, and IP address and port No. of the server that is connected
by the FACTOLINK function, and set these parameters to their correct
values.
FACTOLINK#? IP ADDRESS(???) IS INVALID
The set value (???) of the IP address of the server that is connected by
the FACTOLINK function is in error. Set the IP address of the server that
is connected by the FACTOLINK function to the correct value.
FACTOLINK#? PORT NUMBER(???) IS INVALID
The set value (???) of the port No. of the server that is connected by the
FACTOLINK function is in error. Set the port No. of the server that is
connected by the FACTOLINK function to the correct value.
ALREADY CONNECTED.
The connection request was issued again to an already connected port.
FAIL TO CONNECT SOCKET.
Failed to connect to the FACTOLINK server.
Check if the personal computer of the FACTOLINK server is activated
normally.
NOT CONNECTED.
A disconnection request or data send request was issued to a
non–connected port.
(4) FAST_ETH DATA SERVER L LOG screen / DATA SERVER F LOG
screen
This log screen is used to display an error message of the data server
function.
(???) IS NOT AVAILABLE
The host computer with the IP address (???) cannot be found on the
network. Check if the power to the host computer is turned on. Check
also if the data server and host computer are connected to the network
correctly.
LOGIN USER IS INVALID
The login name is incorrect.
Check if a correct login name is set in the parameter for the data server.
PARAMETERS ARE INVALID
The parameters for the connected host are incorrect.
Check if the parameters of the data server related to the connected host
are set correctly.