7. PARAMETERS
429
08302 Simple synchronous control M series
#0 ATE : Automatic setting of grid positioning for
simplified synchronous control one pair is
disabled (0)/enabled (1)
#1 ATS : Automatic setting of grid positioning for
simplified synchronous control one pair is not
started (0)/started (1)
#3 SSE : In simple synchronization control, the external
machine coordinate system shift function for
the slave axis is, not used (0)/used (1)
#7 SMA : When APZx (PRM1815#4) is turned off for one
axis under simple synchronous control, APZx
for the other axis under simple synchronous
control is, not turned off (0)/turned off (1)
08303 Simple synchronous control <Axis>
M series
#0 ATEx : In simple synchronous control, automatic
setting for grid positioning is disabled (0)/
enabled (1)
#1 ATSx : In simple synchronous control, automatic
setting for grid positioning is not started (0)/
started (1)
#7 SOFx : In simple synchronous control, the
synchronization function is not used (0)/used
(1)
08304 Single directional synchronization function <Axis>
M series
#0 USD : In simple synchronous control, the single
directional synchronization function uses axis
of which machine coordinate is, larger as the
reference (0)/smaller as the reference (1)
Set the
same
value for
the master
axis and
slave axis.
08305 Single directional synchronization function M series
#0 USC : In simple synchronous control, the single
directional synchronization function is, not
used (0)/used (1)
#0 USE : In simple synchronous control, after
emergency stop, the single directional
synchronization function is, used (0)/not used
(1)
PRM
8301#7=1
or
8303#7=1
PRM
8301#7=1
or
8303#7=1