] represents the continuous menu key at the right end. On the
screen, a + mark is indicated.
* How many times you need to press [
] depends on the configuration
and settings. So, when [
] → [?] is indicated, press [ ] repeatedly
until the [?] soft key appears. Depending on the configuration and
settings, the [?] soft key may not appear.
* When “At power–up” is indicated for “Mode,” you need to turn on the
power while holding down a key indicated for operation.
* When an input/output operation is performed using an I/O device (such
as an RS–232C I/O device and memory card), parameter settings are
separately required. (See PRM20 and related parameters.)
Reset
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Operating
time
–
POS
[(OPRT)] [TIME: 0] →
[EXEC]
Number of
machined
parts
–
POS
[(OPRT)] [PART: 0] →
[EXEC]
OT alarm At pow-
er-up
–
and
CAN
Alarm 100 – –
CAN
RESET
while pressing
Registration from MDI
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Parameter f MDI or
emer-
gency
stop
SYSTEM
[PARAM] → Parameter No.
→ [NO.SRH] → Data
→ or [INPUT] →
PWE = 0 →
INPUT
RESET
Offset f –
SETTING
OFFSET
[OFFSET] → Offset No. →
[NO. SRH] → Offset value
→ or [INPUT]
INPUT
Setting
data
f MDI
SETTING
OFFSET
[SETTING] → Setting No. →
[NO. SRH]→Data→
or [INPUT]
INPUT
2. OPERATION LIST
51
About the indication in following tables
* KEYSW: Memory protect signal KEY <
QG0369+
...>
f= Enables writing (KEY signal = 1).
× = Disables writing (KEY signal = 0).
(Some machines are provided with a key or switch that can
operate this signal.)
* PWE = 1: Sets PWE (Parameter Write Enable).
(To be set on the setting screen)
f= Enables parameter rewriting (when PWE is set to 1).
× = Disables parameter rewriting (when PWE is set to 0).
*[