10. PMC
647
* This flag is useful when a user program is used. When the screen
is switched to the PMCMDI screen, PMC control software
determines whether the system initialize the LCD, by checking this
flag. When this flag is on, an application program must initialize the
LCD.
#7
#6 #5 #4 #3 #2 #1 #0
K902
PTCTPRM HIDEPRM
ALWSTP
C–REJECT
FROM–
WRT
#0 FROM–WRT
0: After editing a ladder program, does not automatically write it
to F–ROM.
1: After editing a ladder program, automatically writes it to
F–ROM.
#1 C–REJECT
0: The system activates a C program.
1: The system does not activate a C program.
#2 ALWSTP
0: The execution/stop operation of a sequence program is
disabled.
1: The execution/stop operation of a sequence program is
enabled.
#6 HIDEPRM
0: The display of PMC parameters and the output of PMC
parameters to the outside are enabled.
1: The display of PMC parameters and the output of PMC
parameters to the outside are disabled.
#7 PTCTPRM
0: The modification and reading of PMC parameters are enabled.
1: The modification and reading of PMC parameters are
disabled.
#7
#6 #5 #4 #3 #2 #1 #0
K906
TRCSTAT IOCHK
IOSELSCN
OVRRIDE
#0 OVRRIDE
0: Disables the override function.
1: Enables the override function.
#1 IOSELSCN
0: Does not display the I/O assignment selection function setting
screen.
1: Displays the I/O assignment selection function setting screen.
#2 IOCHK
0: Enables the I/O Link connection check function. (Initial value).
1: Disables the I/O Link connection check function.
#5 TRCSTAT
0: Starts trace operation with the trace function when the
execution soft key is pressed.
1: Starts trace operation with the trace function automatically
after the power is turned on.
CAUTION Be sure to set any unused areas to 0.