7. PARAMETERS
421
08006 Machine lock, in–position check
#1 EML : When PRM8001#0 is set to 1, for PMC axes,
the all axis machine lock signal and
axis–by–axis machine lock signals are
disabled (0)/the all axis machine lock signal is
disabled and the axis–by–axis machine lock
signals are enabled (1)
#2 IPA : For controlled axis at PMC axis control only,
the in–position check is performed when no
move command is issued for the PMC axis
(0)/no in–position check is always performed
(1)
PRM1010
08008 Mirror image <Axis>
#0 MIR : When a PMC axis control command is issued
in mirror image mode, the mirror image is, not
considered (0)/considered (1)
08010 DI/DO group selection for each axis during
PMC axis control
08020 Low–speed feedrate at reference position
return in axis control by PMC (FL)
[Increment system]
<Axis>
PRM1425
08021 Minimum speed of rapid traverse override in
axis control by PMC (Fo) [Increment system]
<Axis>
08022 Upper-limit rate of feed per revolution during
PMC axis control
08028 Linear acceleration/deceleration time constant
for speed commands for PMC axis control
[ms/1000min
–1
]
<Axis>
64) For two-path control
08100 2-path
control
#0 RST : Reset key on the MDI panel effective for both
paths (0)/for the tool post selected by the path
select signal (1)
#1 IAL : When an alarm is raised in one tool post in the
automatic operation mode, the other path
enters the feed hold state and stops (0)/
continues operation without stopping (1)
#5 COF : A separate tool compensation memory area is
used for each path (0)/a common tool
compensation memory area is shared by the
tool posts (1).
#6 DSB : The special single block function is disabled
(0)/enabled (1).
T series
T series
T series
08110 Queuing M code range (minimum value)
2-path
08111 Queuing M code range (maximum value)
control