7
7.2 Parameter List
400
06802 Tool change signal
M series
M series
M series
M series
PRM
6802#3=1
M series
M series
M series
PRM6845
06803 Tool life management
#0 LGR : When the tool life management function is
used, a tool life type is chosen based on the
LTM parameter (bit 2 of parameter No.6800)
for all groups (0)/set to either count or duration
on a group–by–group basis (1)
#1 LFE : When a tool life is specified by count, a count
value from 0 to 9999 can be specified (0)/a
count value from 0 to 65535 can be specified
(1)
T series
PRM
6800#2
06804 Tool life management
#0 TC1 : During automatic operation, preset of the tool
life counter is, disabled (0)/ enabled (1)
#1 ETE : In extended tool life management, as the mark
indicating that the life of the last tool in a group
has expired, ”@” is also used (0)/”*” is used (1)
M series
06810 Tool life control ignored number M series
#0 T99 : If a tool group whose life has expired is found
to exist when M99 is executed in the main
program, the tool change signal is not output
(0)/the tool change signal is output (1)
#1 TCO : When function code 171 or 172 (tool life
management data write) of the PMC window
function is specified, tool data of a tool in the
currently selected group that is currently not in
use, cannot be cleared (0)/can be cleared (1)
#2 E17 : When the management data of the tool in use
is cleared with code 171 or 172 (tool life
management data rewrite) of the PMC window
function, clear operation is not performed and
the execution ends normally (0)/clear operation
is not performed and completion code 13 is
output (1)
#3 GRP : As management data for the tool life arrival
notice signal <
IF0516
>, PRM6844 and 6845
are used (0)/the value set for each group with
the extended tool life management function is
used (1)
#4 ARL : The tool life arrival notice signal <
IF0516
> is,
output for each tool (0)/output for the last tool
in a group (1)
#5 TGN : In tool life management B, the arbitrary group
number set function is, not used (0)/used (1)
#6 TSK : When the life is specified by time and the last
tool in a group is skipped, the count for the last
tool indicates the life value (0)/the count for the
last tool is not changed (1)
#7 RMT : Specifies when to turn off the tool life arrival
signal<
IF0516
> , as follows, the actual
remaining life is longer than that specified in a
parameter (0)/the actual remaining life is not
equal to that specified in a parameter (1)