19. MAINTENANCE FUNCTION
951
[Alarm for backup] This check box is used to set the interval in days at which
a message appears to prompt the user for manual saving when the system
operates for an extended period of time.
19.5.4.4 Option setting screen (160i/180i/210i only)
On the option setting screen, application programs can be registered. When
a program uses the data window library, the program does not run unless it
is started after the work area for the data window library is initialized. By
registering such a program in Ncboot32.exe, it can be executed after the
initialization of the work area for the data window library.
Application programs are registered for each node.
[Node] selects a node. In the list box in the center of the screen, the
programs registered for the selected node are displayed.
[New...] registers a new program. When a blank character is included in the
path, it is enclosed with double quotation marks.
[Remove] deletes a selected line.
[Edit] allows editing of a selected line. This button is used to edit arguments.
The character string %d in the command line is replaced by a node number.
To represent % itself, describe %%.
Example: To start basic operation package 1 after initialization of the work
area for the data window library of the node, describe the following:
“C:\Program Files\Basic Operation Package 1\WinBOP32.exe”
/Node=%d
NOTE For the 160is/180is/210is, the option setting screen is not pro-
vided.