1
1.6 Screen Operation Associated with
<OFFSET SETTING>
38
C
(Software operator’s panel general–purpose switch screen)
: J OFF ON
: J OFF ON
: J OFF ON
: J OFF ON
: J OFF ON
: J OFF ON
: J OFF ON
: J OFF ON
ACTUAL POSITION (ABSOLUTE)
X 0.000 Y 0.000
Z 0.000 B 0.000
>_
MACRO
[][][][][]
MENU OPR
OPERATOR’S PANEL 01234 N12345
MDI **** *** *** 16:05:59
(2) Related signals
#7
#6 #5 #4 #3 #2 #1 #0
IF0577+
OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
IF0585+
ZRNO MD4O MD2O MD1O
IF0601+
SPO KEYO DRNO MLKO SBKO BDTO
IF0609+
ROV2O ROV1O
MP2O MP1O
IF0617+
RTO
HS1DO HS1CO HS1BO HS1AO
IF0625+
*FV7O *FV6O *FV5O *FV4O *FV3O *FV2O *FV1O *FV0O
IF0633+
*JV7O *JV6O *JV5O *JV4O *JV3O *JV2O *JV1O *JV0O
IF0641+
*JV15O *JV14O *JV13O *JV12O *JV11O *JV10O *JV9O *JV8O
IF0649+
–J4O +J4O –J3O +J3O –J2O +J2O –J1O +J1O
(3) Cautions
D The function outputs the F signal according to screen operation. To
control the machine actually, the corresponding ladder needs to be
created.
D A feed operation (PRM7200#1, 7210–7217) along an axis with MDI
keys such as
is enabled only when the software
operator’s panel is displayed. (Output to <
IF0649+
> is performed.)