10. PMC
639
10.1.2.4 Trace function
(1) Trace parameter screen (first page)
<1> Press the system key, then press the [PMC] soft key.
<2> Press the [PMCDGN] soft key.
<3> Press the [TRACE] soft key.
<4> Press the [SETING] soft key on the signal trace screen.
a) SAMPLING/MODE
Set a sampling mode.
D TIME CYCLE : Sampling based on a period
of time
D SIGNAL TRANSITION : Sampling based on signal
transitions
b) SAMPLING/RESOLUTION
Set the resolution of sampling.
c) SAMPLING/TIME
This item is displayed when “TIME CYCLE” is selected as the
sampling mode. Set a time interval for sampling.
d) SAMPLING/FRAME
This item is displayed when “SIGNAL TRANSITION” is
selected as the sampling mode. Set the number of sampling
times.
e) STOP CONDITION
Set a trace stop condition.
D NONE : Does not stop trace operation
automatically.
D BUFFER FULL : Stops trace operation automatically
when the sampling buffer becomes full.
D TRIGGER : Stops trace operation automatically by
a trigger.
f) STOP CONDITION/TRIGGER/ADDRESS
This item becomes settable when “TRIGGER” is set as the
trace stop condition. Set a trigger address for stopping trace
operation.
g) STOP CONDITION/TRIGGER/MODE
This item becomes settable when “TRIGGER” is set as the
trace stop condition. Set a trigger mode for stopping trace
operation.