6
6.2 Stand–Alone Type i Series Hardware
230
Name 1
(*6)
Name 2
(*6)
Color Status
GR1 +5V Green Lights when +5V is supplied.
GR2 HDD Green Lights when the HDD is accessed.
GR3 CNC Green Lights when the CNC operates normally.
GR4 CRD Green Lights when PCMCIA is accessed.
RE1 BUS Red Lights when transfer over the HSSB is
interrupted. Possible causes are
shown below.
S The CNC unit is not powered.
S The optical fiber cable is not
connected.
S The interface on the CNC side failed.
S The CNC display unit with PC
functions or the PANEL i failed.
RE2 BAT Red Indicates a battery alarm. Replace the
battery installed in the CNC display unit
with PC functions or in the PANEL i.
RE3 FAN Red Lights when the basic unit fan or HDD
fan stops. Replace the failed fan.
RE4 TRM Red Indicates a temperature alarm. This
LED lights when the CPU detects a
high temperature that falls outside the
use range. (This decreases the operat-
ing speed of the CPU.)
*6: These labels may vary with the drawing number or version number of
the main board.
D Short plug settings
Short
plug
Settings Location
SW5
SW7
(A20B–
2100–
0690 to –
0693)
Reserved Do not
change the
factory–set
defaults.
SW5
SW7
: Open
: Short
: Short
SW5
TM7
(A20B–
2100–
0780 to –
0785)
Reserved Do not
change the
factory–set
defaults.
SW5
TM7
(PANEL i)
Open (CNC
display unit
with PC
functions)
TM10 Reserved This short
plug is pro-
vided for
testing pur-
pose.
Be sure to
insert this
plug.
TM10
: Short