13. DIAGNOSIS INFORMATION
761
13.2.6 Digital servo or serial pulse coder alarm information
(DGN200 – 280)
#7
#6 #5 #4 #3 #2 #1 #0
200
OVL
DGN
LV OVC HCA HVA DCA FBA OFA
OFA : Overflow alarm
FBA : Disconnection alarm
DCA : Discharge alarm
HVA : Overvoltage alarm
HCA : Abnormal current alarm
OVC : Over current alarm
LV : Insufficient voltage alarm
OVL : Overload alarm
#7
#6 #5 #4 #3 #2 #1 #0
201
ALD
DGN
EXP
ALD EXP
Details of amplifier alarm
When Overload 0 – Motor overheat
DGN200#7
OVL = 1
alarm
1 – Amplifier overheat
When Disconnection 1 0 Built–in pulse coder (hard)
DGN200#1
FBA = 1
alarm
1 1 Disconnection of separate type
pulse coder (hard)
0 0 Disconnection of pulse coder
(software)
#7
#6 #5 #4 #3 #2 #1 #0
202DGN
CSA BLA PHA RCA BZA CKA SPH
SPH : Serial pulse coder or feedback cable is faulty.
Counting of feedback signal is erroneous.
CKA : Serial pulse coder is faulty.
Internal block stopped.
BZA : Battery voltage became 0.
Replace the battery and set the reference position.
RCA : Serial pulse coder is faulty.
Counting of rotation speed is erroneous.
PHA : Serial pulse coder or feedback cable is erroneous.
Counting of feedback signal is erroneous.
BLA : Battery voltage is low (warning)
CSA : Hardware of serial pulse coder is abnormal