7. PARAMETERS
399
06801 Tool life management
#1 TSM : When a tool takes several tool numbers, life is
counted for each of the same tool numbers (0)/
for each tool (1)
#2 LFV : Specifies whether life count override is
disabled (0) / enabled (1) when the extended
tool life management function is used.
#3 EMD : Specifies when an asterisk (*) indicating that a
tool has been exhausted is displayed.
When the next tool is selected (0) / When the
tool life is exhausted (1)
#5 E1S : When the life of a tool is measured in
time–based units, the life is counted every four
seconds (0)/every second (1)
#6 EXG : Using G10, tool life management data is
registered after data for all tool groups has
been cleared (0)/data can be
added/modified/deleted for a specified group
only (1).
#6 EXT : Specifies whether the extended tool life
management function is not used (0) / is used
(1)
#7 M6E : When T code is specified in the same block as
M06, the T code is processed as a next
selected group number/the tool group life is
counted immediately
T series
M series
M series
PRM
6800#2
T series
M series
M series
PRM
6800#7