OPERATION
B–63444EN/01
8. DATA INPUT/OUTPUT
285
Parameters are loaded into the memory of the controller unit from a
floppy. The input format is the same as the output format. See Section
8.6.2. When a parameter is loaded which has the same data number as a
parameter already registered in the memory, the loaded parameter
replaces the existing parameter.
Inputting parameters
1 Make sure the input device is ready for reading.
2 When using a floppy, search for the required file according to the
procedure in Section
8.2.
3 Press the EMERGENCY STOP button on the machine operator’s
panel.
4 Press function key
OFFSET
SETTING
.
5 Press the soft key
[SETING] for chapter selection.
6 Enter 1 in response to the prompt for writing parameters (PWE).
Alarm P/S100 (indicating that parameters can be written) appears.
7 Press soft key
SYSTEM
.
8 Press chapter selection soft key
[PARAM].
9 Press soft key
[(OPRT)].
10 Press the rightmost soft key
(next–menu key).
11 Press soft keys
[READ] and [EXEC].
Parameters are read into memory. Upon completion of input, the
“INPUT” indicator at the lower–right corner of the screen disappears.
12 Press function key
OFFSET
SETTING
.
13 Press soft key
[SETING] for chapter selection.
14 Enter 0 in response to the prompt for writing parameters.
15 Turn the power to the NC back on.
16 Release the EMERGENCY STOP button on the machine operator’s
panel.
1 Press the EMERGENCY STOP button on the machine side.
2 The parameter screen is selected by pressing the <PARAM> key.
3 Set PWE on the setting screen to 1. Alarm PS100 is displayed at this
time.
4 Perform the same operation as for program input.
8.6
INPUTTING AND
OUTPUTTING
PARAMETERS
8.6.1
Inputting Parameters
Procedure (CRT/MDI)
Procedure (DPL/MDI)