OPERATION11. SETTING AND DISPLAYING DATA
B–63444EN/01
348
In some cases, tool compensation values cannot be input because of the
settings in bits 0 (WOF) of parameter 3290. The input of tool
compensation values from the MDI can be inhibited for a specified range
of offset numbers. The first offset number for which the input of a value
is inhibited is set in parameter No. 3294. The number of offset numbers,
starting from the specified first number, for which the input of a value is
inhibited is set in parameter No. 3295.
Consecutive input values are set as follows:
1) When values are input for offset numbers, starting from one for which
input is not inhibited to one for which input is inhibited, a warning is
issued and values are set only for those offset numbers for which input
is not inhibited.
2) When values are input for offset numbers, starting from one for which
input is inhibited to one for which input is not inhibited, a warning is
issued and no values are set.
When offset values have been changed during automatic operation, bit 4
(LGT) and bit 6 (LWM) of parameter 5002 can be used for specifying
whether new offset values become valid in the next move command or in
the next T code command.
LGT LWM
0 0 Become valid in the next T code block
1 0 Become valid in the next T code block
0 1 Become valid in the next move command
1 1 Become valid in the next move command
1 Press the <VAR> key to display the offset screen.
2 Use the cursor keys or enter <No.><(number key)><INPUT> to
display the offset number to be set.
T001X 0.000
T001Z 0.000
3 Display the desired X, Z, R, and T addresses with the cursor keys.
4 Enter a value using the data input keys.
5 Press the <INPUT> key. The each setting value is input and
displayed.
A decimal point can be used when entering a compensation value.
A tool offset value can be set by measuring the tool offset as described in
the next subsection.
D Disabling entry of
compensation values
D Changing offset values
during automatic
operation
Procedure for DPL/MDI
Explanations
D Decimal point input
D Other method