1 Press the <VAR> key to display the settings screen.
> TVON=0
ISO=1
2 Use the cursor keys to move the cursor to the item to be changed.
3 Enter either “0” or “1”, according to the explanation below.
4 Press <INPUT> key. Each parameter is set and displayed.
Setting whether parameter writing is enabled or disabled.
0 : Disabled
1 : Enabled
Setting to perform TV check.
0 : No TV check
1 : Perform TV check
Setting code when data is output through reader puncher interface.
0 : EIA code output
1 : ISO code output
Setting a program input unit, inch or metric system
0 : Metric
1 : Inch
Using channel of reader/puncher interface.
0 : Channel 0
1 : Channel 1
Setting of whether to perform automatic insertion of the sequence number
or not at program edit in the EDIT mode.
0 : Does not perform automatic sequence number insertion.
1 : Perform automatic sequence number insertion.
Setting of mirror image ON/OFF for each axes. Cannot be set with
DPL/MDI.
0 : Mirror image off
1 : Mirror image on
Specifies whether PMC data can be written from the DPL/MDI.
0 : PMC data cannot be written from the DPL/MDI.
1 : PMC data can be written from the DPL/MDI.
Procedure for DPL/MDI
Contents of settings
D PARAMETER WRITE
(PWE)
D TV CHECK (TVON)
D PUNCH CODE (ISO)
D INPUT UNIT (INCH)
D I/O CHANNEL (I/O)
D SEQUENCE NO. (SEQ)
D MIRROR IMAGE
D Writing PMC data (DWE)