B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 105 -
(2) Series 30i
Address Description Unit
0300 Position error pulse of the tapping axis (error) Pulse
0450 Position error pulse of the spindle (error) Pulse
0451 Interpolation pulse of the spindle Pulse
0454 Integrated interpolation pulse of the spindle Pulse
0455
Difference of move command converted for the
spindle (instantaneous)
Pulse
0456
Difference of position error converted for the spindle
(instantaneous)
Pulse
0457
(In terms of spindle) Width of synchronous error
(maximum)
Pulse
NOTE
The data indicated below is displayed only when bit
0 (DGN) of parameter No. 5204 is set to 0. Usually,
set 0.
0455 : Difference of move command converted for
the spindle (instantaneous)
0456 : Difference of position error converted for the
spindle (instantaneous)
0457 : (In terms of spindle) Width of synchronous
error (maximum)
(3) Series 15i
Address Description Unit
1600 Position error pulse of the spindle (instantaneous) Pulse
1601 Position error pulse of the spindle (maximum) Pulse
1602
Position error pulse of the tapping axis
(instantaneous)
Pulse
1603 Position error pulse of the tapping axis (maximum) Pulse
1604
(Value converted for the spindle) Width of
synchronous error (instantaneous)
Pulse
1605
(Value converted for the spindle) Width of
synchronous error (maximum)
Pulse