15i 16i 30i
αi series Bis series
3006#2 4006#2 4006#2 Increment system of spindle speed Unused (Set to 0.)
3006#4 4006#4 4006#4 Reserved Sets the d-phase current command.
3007#5 4007#5 4007#5 Whether to detect a feedback signal disconnection
(*1)
Whether to detect a feedback signal disconnection
(*1)
3007#7 4007#7 4007#7 Reserved Magnetic pole detection start signal selection
3008#3 4008#3 4008#3 Reserved Sets the current command.
3008#5 4008#5 4008#5 Reserved Setting for using the sub module SM
3008#6 4008#6 4008#6 Reserved Reference magnetic pole position selection
3009#5 4009#5 4009#5 Reserved Setting related to magnetic flux reduction speed
3012#6 4012#6 4012#6 Unused (Set to 0.)
Setting of whether to drive the synchronous built-in
spindle motor
3012#7 4012#7 4012#7 Setting of spindle HRV function Setting of spindle HRV function
3013#7 4013#7 4013#7
Setting of a PWM carrier frequency for low-speed
characteristics area
Unused (Set to 0.)
3014#0 4014#0 4014#0 Whether to use the spindle switch function Unused (Set to 0.)
3014#2 4014#2 4014#2
Whether to check both spindle switch main and sub
magnetic contactor contacts
Unused (Set to 0.)
3014#3 4014#3 4014#3
Whether to check both magnetic contactor contacts for
high-speed /low-speed characteristics in speed range
switching
Unused (Set to 0.)
3015#2 4015#2 4015#2 Whether to use the speed range switching function Unused (Set to 0.)
3015#3 4015#3 4015#3 Whether to use the spindle tandem function Unused (Set to 0.)
3016#4 4016#4 4016#4
Setting related to control characteristics on Cs contouring
control/servo mode
Unused (Set to 0.)
3017#0 4017#0 4017#0
This parameter sets speed integration operation when
differential spindle speed control is exercised.
Unused (Set to 0.)
3019#4 4019#4 4019#4
Setting of the function for switching from high-speed
characteristics to low-speed characteristics with the speed
detection signal SDT = 1 at speed range switching
Unused (Set to 0.)
3024 4024 4024 Zero speed detection level (SST)
(*1)
Zero speed detection level (SST)
(*1)
3039 4039 4039 Slip compensation gain Unused (Set to 0.)
3080 4080 4080
Regenerative power limit for high-speed zone/regenerative
power limit
Regenerative power limit
3083 4083 4083 Motor voltage on velocity control mode
Current ratio/motor stop confirmation time in
magnetic pole detection operation
3084 4084 4084 Motor voltage on orientation AMR offset
3085 4085 4085
Motor voltage on servo mode/spindle synchronous control
mode
AMR offset fine adjustment
3086 4086 4086 Motor voltage on Cs contouring control Inductance ratio
3097 4097 4097 Feedback gain of spindle speed Unused (Set to 0.)
3102 4102 4102 Excitation voltage saturation speed at no-load Base speed
3103 4103 4103 Base speed limit ratio Magnetic flux reduction speed at maximum load
3109 4109 4109
Filter time constant for processing saturation related to the
voltage command
Unused (Set to 0.)
3111 4111 4111 Secondary current coefficient Maximum current constant
3113 4113 4113 Slip constant Current constant for magnetic flux reduction
3114 4114 4114
Slip compensation coefficient for a high-speed zone/slip
compensation coefficient at deceleration
Unused (Set to 0.)