B-65280EN/05 APPENDIX A.SPINDLE PARAMETER TABLE
- 647 -
Application
Internal
data No.
F-xxx
15i 16i 30i
bit
Standard
initial setting
data
Contents
MH ML SH SL
Classifi
-cation
Reference
item
#7 0
Inter-SPM communication master axis setting
O O B Ι-5.8.8
Ι-5.11.4
336L 3353 4353 4353 #1 0 Velocity feedback signal setting in torque tandem
operation
O O B Ι-5.11.6
#2 0 Relationship of master/slave motor rotation directions in
torque tandem operation
O O B Ι-5.11.6
337 3354 4354 4354 0 Excessive semi-closed loop/closed loop position error
alarm detection level [in Cs contour control]
O O A Ι-1.5.10
338 3355 4355 4355 0 Motor sensor signal amplitude ratio compensation O O A Ι-1.3.2
Ι-4.3
339 3356 4356 4356 0 Motor sensor signal phase difference compensation O O A Ι-1.3.2
Ι-4.3
340 3357 4357 4357 0 Spindle sensor signal amplitude ratio compensation O O A Ι-1.3.2
Ι-4.3
341 3358 4358 4358 0 Spindle sensor signal phase difference
compensation
O O A Ι-1.3.2
Ι-4.3
343 3360 4360 4360 0 Preload value O O B Ι-5.10.6
344 3361 4361 4361 0 Number of spindle sensor arbitrary teeth O O A Ι-1.3.2
345 3362 4362 4362 0 Load meter compensation 1 O C Ι-2.6.4
346 3363 4363 4363 0 Load meter compensation 2 O C Ι-2.6.4
347 3364 4364 4364 0 Load meter compensation 3 O C Ι-2.6.4
348 3365 4365 4365 0 Load meter compensation 1 O C App. B
349 3366 4366 4366 0 Load meter compensation 2 O C App. B
350 3367 4367 4367 0 Load meter compensation 3 O C App. B
352 3369 4369 4369 0 Spindle synchronous orientation deceleration
coefficient
O O B Ι-5.5.6
356H 3373 4373 4373 #1 0 Setting of the peak hold function for load meter
output
O O B App. B
358 3376 4376 4376 0 Load meter compensation 1 O C App. B
359 3377 4377 4377 0 Load meter compensation 2 O C App. B
360 3378 4378 4378 0 Load meter compensation 3 O C App. B
361 3379 4379 4379 0 Load meter compensation 1 O C App. B
362 3380 4380 4380 0 Load meter compensation 2 O C App. B
363 3381 4381 4381 0 Load meter compensation 3 O C App. B
366 3384 4384 4384 0 Spindle EGB : Maximum acceleration/deceleration
value in automatic phase matching
O O B Ι-5.8.8
367 3385 4385 4385 0 Spindle EGB : time constant for free-running phase
matching
O O B Ι-5.8.8
368 3386 4386 4386 0 Spindle EGB : master side detector pulse count O O B Ι-5.8.8
369 3387 4387 4387 0 Spindle EGB : synchronous ratio numerator O O B Ι-5.8.8
370 3388 4388 4388 0 Spindle EGB : synchronous ratio denominator O O B Ι-5.8.8
373 3391 4391 4391 0 Resonance elimination filter 1 : attenuation center
frequency
O O B Ι-4.2.2
374 3392 4392 4392 0 Resonance elimination filter 1 : attenuation
bandwidth
O O B Ι-4.2.2
375 3393 4393 4393 0 Resonance elimination filter 1 : damping O O B Ι-4.2.2
376H 3394 4394 4394 #2 0 Setting of the detection lower limit of the
one-rotation signal
O O A Ι-1.3.2
#3 0 Setting of the fine acceleration/deceleration (FAD)
function
O O B Ι-5.6.4
#4 0 Acceleration/deceleration type of fine
acceleration/deceleration (FAD)
O O B Ι-5.6.4
#5 0 Whether to detect the alarm related to spindle
sensor polarity erroneous setting
O O A Ι-1.3.2
376L 3395 4395 4395 #3 0 Setting of parameter transfer from the CNC to
spindle software
O O O O B Ι-2.6.4
#6 0 Triggering of the disturbance input function
(vibration application function)
O O B Ι-4.2.3