5.FUNCTION DESCRIPTIONS FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 608 -
15i 16i 30i
3075 4075 4075
Orientation completion signal detection level (effective area for in-position
check)
Unit of data : ±1 pulse unit (360 degrees/4096)
Valid data range : 0 to 100
Standard setting value : 10
This data is used to set the detecting level of orientation completion
signal (ORARA). ORARA = 1 is satisfied if the position error is
within the setting.
15i 16i 30i
3077 4077 4077
Orientation stop position shift value
Unit of data : ±1 pulse unit (360 degrees/4096)
Valid data range : -4095 to 4095
Standard setting value : 0
This data is used to specify the shift amount of the spindle orientation
stop position. If a positive value is specified, the position where the
spindle stops is shifted counterclockwise.
15i 16i 30i
3320 4320 4320
Acceleration during motor deceleration (HIGH) CTH1A=0, CTH2A=0
3321 4321 4321
Acceleration during motor deceleration (MEDIUM HIGH) CTH1A=0, CTH2A=1
3322 4322 4322
Acceleration during motor deceleration (MEDIUM LOW) CTH1A=1, CTH2A=0
3323 4323 4323
Acceleration during motor deceleration (LOW) CTH1A=1, CTH2A=1
Unit of data : 10min
-1
/sec
Valid data range : 0 to 6400
Standard setting value : 0
This data is used to specify the acceleration during motor deceleration
for high-speed spindle orientation. If the setting is "0", the high-speed
spindle orientation function is disabled, and the standard-type spindle
orientation function is enabled. The setting for the parameter is
obtained, using:
Acceleration during deceleration =
0.9)(0.8
2
60
to
J
××
π
τ
where τ(Nm) : Motor maximum torque at spindle orientation speed
upper limit (parameter No. 4038)
J(kgm
2
) : Motor inertia + load inertia