4.ADJUSTMENT FANUC AC SPINDLE MOTOR αCi series B-65280EN/05
- 484 -
(4) Spindle synchronous control
15i 16i 30i
- 4044 4044
Velocity loop proportional gain on spindle synchronous control (HIGH)CTH1A=0
- 4045 4045
Velocity loop proportional gain on spindle synchronous control (LOW) CTH1A=1
Unit of data :
Valid data range : 0 to 32767
Standard setting value : Depends on the motor model.
15i 16i 30i
- 4052 4052
Velocity loop integral gain on spindle synchronous control (HIGH) CTH1A=0
- 4053 4053
Velocity loop integral gain on spindle synchronous control (LOW) CTH1A=1
Unit of data :
Valid data range : 0 to 32767
Standard setting value : Depends on the motor model.
NOTE
For the velocity loop gain on spindle synchronous
control and on the servo mode, common parameters
are used.