B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 169 -
SPDUNT Sets the unit of speed.
0 : Sets the 1 min
-1
unit.
1 : Sets the 10 min
-1
unit.
When a type of motor whose maximum speed exceeds 32767 min
-1
is
used, set this parameter to 1.
The setting of this parameter changes the increment systems of the
parameters listed in the table below.
Parameter No.
Increment system of
parameter
15i 16i 30i
Description
1 min
-1
unit 10 min
-1
unit
3020 4020 4020
Maximum motor speed
1min
-1
10min
-1
3021 4021 4021
Maximum spindle speed on Cs contouring
control
1min
-1
10min
-1
3030 4030 4030
Soft start/stop setting time
1min
-1
/sec 10min
-1
/sec
3032 4032 4032
Acceleration on spindle synchronous control
1min
-1
/sec 10min
-1
/sec
3033 4033 4033
Spindle synchronous speed arrival level
1min
-1
10min
-1
3074 4074 4074
Reference position return speed on Cs
contouring control/servo mode
1min
-1
10min
-1
3098 4098 4098
Maximum speed for position feedback signal
detection
1min
-1
10min
-1
3100 4100 4100
Base speed for motor output specification
1min
-1
10min
-1
3102 4102 4102
Excitation voltage saturation speed with no load
1min
-1
10min
-1
Low-speed characteristics parameters (when the speed range switching control function is used)
3108 4108 4108
Current loop integral gain zero speed
1min
-1
10min
-1
3138 4138 4138 Base speed for motor output specification 1min
-1
10min
-1
3140 4140 4140 Excitation voltage saturation speed with no load 1min
-1
10min
-1
3144 4144 4144 Current loop integral gain zero speed 1min
-1
10min
-1
3160 4160 4160 Speed detection level hysteresis 1min
-1
10min
-1
NOTE
Usually, set the 1 min
-1
unit (by setting the
parameter to 0).
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3009 4009 4009
LDTOUT VLPGAN
VLPGAN Velocity control loop gain increment system
0 : Uses ordinary setting.
1 : Divides ordinary setting data by 16 for processing.
NOTE
Usually, set this parameter to 0.