2.EXPLANATION OF OPERATION MODES FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 556 -
15i 16i
3406 4406
Acceleration/deceleration time constant at return to the reference position in
Cs contouring control
Unit of data : 1msec
Valid data range : 0 to 32767
Standard setting : 0
This parameter sets the acceleration to be used for returning to the
reference position in Cs contouring control. Use of this parameter can
reduce the shock due to acceleration/deceleration during return to the
reference position. The spindle speed command during return to the
reference position is then given as follows:
Reference
position return
speed
(min
-1
)
Setting in
parameter No.
4406
(msec)
Setting in
parameter No.
4406
(msec)
Start of reference position return
One-rotation signal detected
End of reference position return
NOTE
1 When 0 is set in this parameter, a velocity command
is assumed as follows.
• Before detecting the one-rotation signal:
Reference position return speed (step-type
velocity command)
• After detecting the one-rotation signal:
Distance to the reference position × Position gain
2 This parameter is enabled when soft start/stop signal
SOCNA is 1.
2.4.8 Diagnosis (Diagnosis Screen)
For this subsection, see Subsection 2.4.8, "Diagnosis (Diagnosis
Screen)", in Part I.