1.START-UP FANUC AC SPINDLE MOTOR αi series B-65280EN/05
- 6 -
1.2.2 Automatic Spindle Parameter Initialization
(1) Parameter list
Parameter No.
15i 16i 30i
Description
5607#0 4019#7 4019#7 Function for automatically initializing spindle parameters
3133 4133 4133 Spindle motor model code
(2) Procedure for automatic spindle parameter initialization
Perform automatic spindle parameter initialization by following the
procedure below.
<1> Set the model code for the desired motor for automatic parameter
initialization.
Parameter No.
15i 16i 30i
Description
3133 4133 4133 Model code
NOTE
1 The control method usable with the αi series
spindle is spindle HRV control only. The
conventional control method is not supported.
2 When using a spindle motor that has no model
code, set model code "300" ("400" for a spindle
motor with speed range switching control) for
automatic parameter setting, then manually input
data according to the parameter table for each
motor model.
<2> Set the relevant parameter to enable automatic spindle parameter
initialization.
Parameter No.
15i 16i 30i
Description
4019#7 4019#7 1
5607#0
0
NOTE
This bit is reset to its original value after
automatic parameter initialization.
<3> Turn the CNC off, then on again. Then, the spindle parameters
specified with a model code are automatically initialized.