B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 5.FUNCTION DESCRIPTIONS
- 345 -
15
i 16i 30i
3064 4064 4064
Ratio of position gain change upon completion of spindle orientation
Unit of data : 1%
Valid data range : 0 to 1000
Standard setting value : 100
This data is used to set a position gain change ratio upon completion
of orientation.
15
i 16i 30i
3075 4075 4075
Orientation completion signal detection level (effective area for in-position
check)
)
Unit of data : ±0.1deg
Valid data range : 0 to 100
Standard setting value : 10
This data is used to set the detecting level of orientation completion
signal (ORARA).
The orientation completion signal (ORARA) is set to 1 if the spindle
position is within the set data range when orientation is stopped.
When the orientation command (ORCMA) is turned off (= 0), the
orientation completion signal (ORARA) is set to 0.
15
i 16i 30i
3076 4076 4076
Spindle orientation speed limit ratio
Unit of data : 1%
Valid data range : 0 to 100
Standard setting value : 33
This data is used to set an orientation speed limit ratio.
Position gain
Speed
limit ratio
Orientation
speed
(motor speed)
= 60
×
100
× gear ratio ×
100
[min
-1
]
15
i 16i 30i
3077 4077 4077
Orientation stop position shift value
Unit of data : ±0.01deg
Valid data range : -100 to 100
Standard setting value : 0
This data is used to shift the stop position.
When a plus (+) value is set, the spindle stop position is shifted in the
CCW direction by the set number of pulses.