B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 109 -
2.4 Cs CONTOURING CONTROL
Optional function
2.4.1 Start-up Procedure
A. Check that operation in the velocity control mode is enabled.
B. Prepare and check the ladder program for the Cs contouring control
function.
C. Set the necessary parameters for Cs contouring control.
D. Check and adjust the waveforms on the Cs contouring control detector.
E. Check the operation of reference position return.
- Direction of return to the reference position in Cs contouring control
mode
- Maximum speed in Cs contouring control mode
- Feedrate at which return to the reference position is performed in Cs
contouring control mode
- Parameter for the rate of change in the position gain for return to the
reference position in Cs contouring control mode
F. Check the stop position when return to the reference position is
performed.
- Grid shift in Cs contouring control mode
G. Check the direction of spindle rotation in Cs contouring control mode.
- Parameter specifying the direction of rotation for a positive (+) motion
command
H. Adjust and check the Cs contouring control servo system.
(Check the operation in jog mode, rapid traverse mode, handle mode,
and other modes.)
- Position gain in Cs contouring control mode
- Velocity loop proportional gain in Cs contouring control mode
- Velocity integral gain in Cs contouring control mode
- Motor voltage in Cs contouring control mode
- Disturbance torque compensating constant (acceleration feedback gain)
- Spindle speed feedback gain
I. End of operation check in Cs contouring control mode