B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 5.FUNCTION DESCRIPTIONS
- 269 -
15
i 16i 30i
3077 4077 4077
Orientation stop position shift value
Unit of data : ±1 pulse unit (360 degrees/4096)
Valid data range : -4095 to 4095
Standard setting value : 0
This data is used to specify the shift amount of the spindle orientation
stop position. If a positive value is specified, the position where the
spindle stops is shifted counterclockwise.
15
i 16i 30i
3084 4084 4084
Motor voltage setting on orientation
Unit of data : 1%
Valid data range : 0 to 100
Standard setting value : Depends on the motor model.
This data is used to specify the motor voltage for spindle orientation.
For high-speed spindle orientation, usually specify "100".
15
i 16i 30i
3320 4320 4320
Acceleration during motor deceleration (HIGH) CTH1A=0, CTH2A=0
3321 4321 4321
Acceleration during motor deceleration (MEDIUM HIGH) CTH1A=0, CTH2A=1
3322 4322 4322
Acceleration during motor deceleration (MEDIUM LOW) CTH1A=1, CTH2A=0
3323 4323 4323
Acceleration during motor deceleration (LOW) CTH1A=1, CTH2A=1
Unit of data : 10min
-1
/sec
Valid data range : 0 to 6400
Standard setting value : 0
This data is used to specify the acceleration during motor deceleration
for high-speed spindle orientation. If the setting is "0", the high-speed
spindle orientation function is disabled, and the standard-type spindle
orientation function is enabled. The setting for the parameter is
obtained, using:
Acceleration during deceleration =
0.9)to(0.8
2
60
J
××
π
τ
where
τ(Nm) : Motor maximum torque at spindle orientation speed upper
limit (parameter No. 4038)
J(kgm2) : Motor inertia + load inertia