B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 163 -
2.6.3 Parameters
This subsection describes those parameters that are common to all
operation modes by dividing them into several types.
NOTE
For the detector-related parameters, see Section
1.3, "PARAMETERS RELATED TO DETECTORS",
in Part I.
(1) List of parameters specific to spindle motor driving
This item provides a list of the motor parameters specific to spindle
motor driving (with no speed range switching). Usually, the settings of
these parameters need not be changed. Use the values indicated on a
parameter table for each motor model without modification.
Parameter No.
15i 16i 30i
Description
3006#2 4006#2 4006#2 Sets the unit of speed.
3008#4 4008#4 4008#4 Sets the method of output control.
3011#3 4011#3 4011#3 Sets the number of motor poles.
3011#4 4011#4 4011#4 Sets a maximum output for acceleration/deceleration.
3011#7 4011#7 4011#7 Sets the number of motor poles.
3012#2,#1,#0 4012#2,#1,#0 4012#2,#1,#0 Sets a PWM carrier frequency.
3012#7 4012#7 4012#7 Sets the spindle HRV function.
3013#6 to #2 4013#6 to #2 4013#6 to #2 Sets current dead-band data.
3013#7 4013#7 4013#7
Sets a PWM carrier frequency in low-speed characteristics area of
speed range switching.
3020 4020 4020 Maximum motor speed
3039 4039 4039 Slip compensation coefficient
3080 4080 4080 High-speed area regenerative power limit/regenerative power limit
3083 4083 4083 Motor voltage on velocity control
3084 4084 4084 Motor voltage on orientation
3085 4085 4085 Motor voltage on servo mode/spindle synchronous control
3086 4086 4086 Motor voltage on Cs contouring control
3100 4100 4100 Base speed for motor output specification
3101 4101 4101 Torque limitation value for motor output specification
3102 4102 4102 Excitation voltage saturation speed with no load
3103 4103 4103 Base speed limit ratio
3104 4104 4104 Current loop proportional gain
3106 4106 4106 Current loop integral gain
3108 4108 4108 Current loop integral gain zero speed
3109 4109 4109 Filter time constant in voltage command saturation processing
3110 4110 4110 Current conversion constant
3111 4111 4111 Secondary current coefficient