2.EXPLANATION OF OPERATION MODES FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 520 -
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3009 4009 4009
OVRTYP LDTOUT
LDTOUT Whether to output the load detection signals (LDT1 and LDT2) during
acceleration/deceleration
0 : Not output during acceleration/deceleration. (standard setting
value)
1 : Output (at all times) during acceleration/deceleration if the
parameter-set level is exceeded.
OVRTYP Analog override type
0 : Override of linear function type (standard setting value)
1 : Override of quadratic function type
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3012 4012 4012
SPHRV SYSP
SYSP Sets whether to drive the synchronous built-in spindle motor.
0 : Enables inductive spindle motor driving. (standard setting value)
1 : Enables synchronous built-in spindle motor driving.
Set to “1”.
SPHRV Sets the spindle HRV control function.
0 : Disables spindle HRV control.
1 : Enables spindle HRV control. (standard setting value)
Set to “1”.
NOTE
When driving the Bis series spindle (synchronous
built-in spindle motor), be sure to set both of the
SYSP and SPHRV bits to 1.
16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
4019 4019
PRLOAD
PRLOAD Automatic parameter setting function
0 : Does not perform automatic parameter setting. (standard setting
value)
1 : Performs automatic parameter setting.
After setting a desired motor model code in parameter No. 4133 and
setting this bit to 1, turn off the power to the CNC, then turn on the
power to the CNC again. The parameters (No. 4000 to No. 4175) for
the αi series spindle corresponding to the model code are
automatically initialized. Upon completion of automatic setting, this
bit is automatically set to 0.