B-65280EN/05 FANUC AC SPINDLE MOTOR αCi series 2.EXPLANATION OF OPERATION MODES
- 449 -
[Series 15i]
(1) Acc./Dec. type
5605 #1
0 : Exponential type Acc./Dec.
1 : Linear type Acc./Dec. (Standard setting)
NOTE
Usually, linear type acceleration/deceleration (bit 1 of
No. 5605 = 1) is used.
(2) Set Acc./Dec. the time constant of the rigid tapping mode.
<1> The time constant is a fixed value if bit 2 of parameter No.
5605 = 0.
Acc./Dec. time constant 5751
Spindle speed 5757
<2> When bit 2 of parameter No.5605 is set to 1, one of the four
acceleration/deceleration time constants is selected,
depending on the spindle speed.
Spindle speed Acc./Dec. time constant
Gear 1 5886 5884
Gear 2 5889 5887
Gear 3 5892 5890
Gear 4 - 5893