B-65280EN/05 FANUC AC SPINDLE MOTOR αi series 2.EXPLANATION OF OPERATION MODES
- 137 -
NOTE
For details, see below:
Section 9.12, "SPINDLE SYNCHRONOUS CONTROL",
in FANUC Series 16i/18i/21i -MODEL B CONNECTION
MANUAL (FUNCTION) (B-63523EN-1).
Section 11.13, "SPINDLE SYNCHRONOUS
CONTROL", in FANUC Series 30i/31i/32i –MODEL A
CONNECTION MANUAL (FUNCTION) (B-63943EN-1)
Section 9.11, "SPINDLE SYNCHRONOUS CONTROL",
in FANUC Series 0i -MODEL C CONNECTION
MANUAL (FUNCTION) (B-64113EN-1).
2.5.5 I/O Signals (CNC ↔ PMC)
(1) Address list of input signals (PMC → CNC)
16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
Common to all axes G038 G038
SPPHS SPSYC
Common to all axes G032 G032
R08I R07I R06I R05I R04I R03I R02I R01I
Common to all axes G033 G033
SSGN R12I R11I R10I R09I
1st-
G070 G070
SFRA SRVA CTH1A CTH2A
2nd-
G074 G074
SFRB SRVB CTH1B CTH2B
1st-
G071 G071
INTGA
2nd-
G075 G075
INTGB
(2) Details of input signals (CNC → PMC)
(a) Spindle synchronous control signal SPSYC
[Function] Specifies switching to spindle synchronous control mode.
[Operation] When this signal is set to 1, spindle synchronous control mode is set.
When this signal is set to 0, spindle synchronous control mode is
cancelled.
(b) Spindle phase synchronous control signal SPPHS
[Function] Specifies spindle phase synchronous control mode (phase matching).
(i) This function is valid when the spindle synchronous control
signal SPSYC is 1.
(ii) After the spindle synchronous speed control completion signal
FSPSY is set to 1, specify this signal.
(iii) A spindle phase synchronous control operation is performed on
the rising edge of this signal. So, the phase once matched is not
shifted by setting this signal to 0.
However, a phase matching operation is performed when this
signal is changed from 0 to 1 again.
[Operation] When this signal makes a transition from 0 to 1, spindle phase
synchronous control is exercised.