5.8.9 Diagnosis Signal Related to Spindle EGB
Address
16i
Description Unit
0717
Synchronous error between master and slave axes.
(Weight is slave side)
Pulse
NOTE
1 Displaying this data on the CNC diagnosis screen
requires the αi SPM type B and the i series model B
CNC.
2 Displaying this data on the CNC diagnosis screen
requires the following CNC software series/editions.
FS16i/160i/160is-MB :
Series B0H1/R(18) and subsequent editions
FS18i/180i/180is-MB :
Series BDH1/R(18) and subsequent editions
FS18i/180i/180is-MB5 :
Series BDH5/H(08) and subsequent editions
5.8.10 Status Errors Related to Spindle EGB
Error No. Description Measure
33 Invalid hardware configuration Check the model of the CNC in use.
34
An attempt was made to enable both the
spindle EGB and FAD functions.
To use the spindle EGB function, disable the
spindle FAD function.
5.8.11 Alarms