2.EXPLANATION OF OPERATION MODES FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 578 -
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3352 4352 4352
PKHALW
PKHALW Sets the peak hold function for load meter output.
0 : Does not use the peak hold function. (standard setting value)
1 : Uses the peak hold function.
15i 16i 30i
#7 #6 #5 #4 #3 #2 #1 #0
3395 4395 4395
PRIMED
PRIMED Sets parameter transfer from the CNC to spindle software.
0 : Regards parameters as valid one second after they are transferred
from the CNC. (Standard setting value)
1 : Regards parameters as valid as soon as they are transferred from
the CNC.
NOTE
This parameter is valid with 9D53 Series B (02)
edition or later and 9D70 series A (01) edition or
later.
15i 16i 30i
3020 4020 4020
Maximum motor speed
Unit of data : 1min
-1
Valid data range : 0 to 32767
Standard setting value : Depends on the motor model.
This parameter sets a maximum spindle motor speed.
15i 16i 30i
3022 4022 4022
Speed arrival detection level
Unit of data : 0.1%
Valid data range : 0 to 1000
Standard setting value : 150
This parameter sets a speed arrival signal (SARA) detection range.
When the motor speed reaches within ±(setting data/10)% of a
specified speed, the speed arrival signal (SARA) is set to 1.
15i 16i 30i
3023 4023 4023
Speed detection level
Unit of data : 0.1%
Valid data range : 0 to 1000
Standard setting value : 30
This parameter sets a speed detection signal (SDTA) detection range.
When the motor speed is (setting data/10)% of a maximum speed or
less, the speed detection signal (SDTA) is set to 1.