B-65280EN/05 APPENDIX A.SPINDLE PARAMETER TABLE
- 653 -
Internal
data No.
F-xxx
15i 16i 30i
bit
Standard
initial setting
data
Contents
Classifi
-cation
Reference
item
99 3109 4109 4109 Depends on
the model
Filter time constant for processing saturation related to the voltage
command
C ΙΙΙ-2.5.3
100 3110 4110 4110 Depends on
the model
Current conversion constant C ΙΙΙ-2.5.3
101 3111 4111 4111 Depends on
the model
Secondary current coefficient C ΙΙΙ-2.5.3
102 3112 4112 4112 Depends on
the model
Criterion level for saturation related to the voltage command/PWM
command clamp value
C ΙΙΙ-2.5.3
103 3113 4113 4113 Depends on
the model
Slip constant C ΙΙΙ-2.5.3
105 3115 4115 4115 Depends on
the model
PWM command clamp value at deceleration C ΙΙΙ-2.5.3
106 3116 4116 4116 Depends on
the model
Motor leakage constant C ΙΙΙ-2.5.3
107 3117 4117 4117 Depends on
the model
Regular-time voltage compensation coefficient for high-speed
zone/regular-time motor voltage coefficient
C ΙΙΙ-2.5.3
108 3118 4118 4118 Depends on
the model
Acceleration-time voltage compensation coefficient for high-speed
zone/acceleration-time motor voltage coefficient
C ΙΙΙ-2.5.3
109 3119 4119 4119 Depends on
the model
Deceleration-time excitation current change time constant/excitation
current change time constant
C ΙΙΙ-2.5.3
110 3120 4120 4120 Depends on
the model
Dead-band compensation data C ΙΙΙ-2.5.3
111 3121 4121 4121 5 Time constant for changing the torque (TCMD filter time constant) B ΙΙΙ-2.5.4
113 3123 4123 4123 30 Short-time overload detection time D ΙΙΙ-2.5.4
117 3127 4127 4127 Depends on
the model
Value displayed on load meter at maximum output C ΙΙΙ-2.5.3
118 3128 4128 4128 Depends on
the model
Compensation coefficient between the specification and true
base/maximum torque curve compensation coefficient
C ΙΙΙ-2.5.3
120 3130 4130 4130 Depends on
the model
Current loop proportional gain speed coefficient/current phase delay
compensation coefficient
C ΙΙΙ-2.5.3
121 3131 4131 4131 Depends on
the model
Dead-band compensation hysteresis B ΙΙΙ-2.5.3
123 3133 4133 4133 Depends on
the model
Motor model code C ΙΙΙ-2.5.3
124
125
3134 4134 4134 Depends on
the model
Motor overheat detect level (2-word) C ΙΙΙ-2.5.3
152 3160 4160 4160 0 Hysteresis of speed detection level B Ι-5.1.7
304 3320 4320 4320 0 Acceleration at orientation deceleration time (High) B ΙΙΙ-2.2.9
305 3321 4321 4321 0 Acceleration at orientation deceleration time (Medium High) B ΙΙΙ-2.2.9
306 3322 4322 4322 0 Acceleration at orientation deceleration time (Medium Low) B ΙΙΙ-2.2.9
307 3323 4323 4323 0 Acceleration at orientation deceleration time (Low) B ΙΙΙ-2.2.9
312 3328 4328 4328 0 Command multiplication for spindle orientation by position coder B Ι-5.3.6
320 3336 4336 4336 0 Switching point used for an acceleration/deceleration time constant
used for spindle synchronous control
B ΙΙΙ-2.4.8
324 3340 4340 4340 0 Bell-shaped acceleration/deceleration time constant during spindle
synchronous control
B ΙΙΙ-2.4.8