2.EXPLANATION OF OPERATION MODES FANUC AC SPINDLE MOTOR βi series B-65280EN/05
- 376 -
2.6 SPECIFICATIONS COMMON TO ALL OPERATION MODES
2.6.1 Overview
For this subsection, see Subsection 2.6.1, "Overview", in Part I.
2.6.2 List of I/O Signals (CNC ↔ PMC)
For this subsection, see Subsection 2.6.2, "List of I/O Signals (CNC
↔ PMC)", in Part I.
2.6.3 Parameters
For this subsection, see Subsection 2.6.3, "Parameters", in Part I.
2.6.4 Details of parameters
For this subsection, see Subsection 2.6.4, "Details of parameters", in
Part I.
Note that, however, the standard setting value of the following
parameter differs among the βi series spindle motors:
0i
4090
Overload detection level
Unit of data : 1%
Valid data range : 0 to 100
Standard setting value : 95
This parameter sets the condition for detecting a short-time overload
alarm (SPM alarm 29).
If a load more than the set percentage (maximum motor output [load
meter full scale] = 100%) is applied to the spindle motor for a
predetermined time period (set by parameter No. 4123), a short-time
overload alarm (SPM alarm 29) is issued.
2.6.5 Diagnosis (Diagnosis Screen)
For this subsection, see Subsection 2.6.5, "Diagnosis (Diagnosis
Screen)", in Part I.