5.FUNCTION DESCRIPTIONS FANUC AC SPINDLE MOTOR αi series B-65280EN/05
- 284 -
(3) Address list of output signals (CNC → PMC)
(a) For path 1
16
i 30i
#7 #6 #5 #4 #3 #2 #1 #0
F044 F044
SYCAL FSPPH FSPSY
1st- F047 F047
SORENA
2nd- F051 F051
SORENB
(b) For path 2
16
i 30i
#7 #6 #5 #4 #3 #2 #1 #0
F1044 F1044
SYCAL FSPPH FSPSY
1st- F1047 F1047
SORENA
2nd- F1051 F1051
SORENB
(4) Details of output signals (CNC → PMC)
(a) Synchronous orientation permission signal (SORENA)
If this signal is "1", the synchronous orientation command is issued at
the rising edge of the SPPHS signal.
If this signal is "0", the spindle phase synchronous command is issued
at the rising edge of the SPPHS signal. If this signal becomes "0"
during synchronous orientation, the synchronous orientation is
released.
In this case, reset the synchronous speed command for both the
spindles to "0". SORENA (SORENB) = "1" is output if SORSLA
(SORSLB) = "1" is satisfied, and SORENA (SORENB) = "0" is
output if SORSLA (SORSLB) = "0" is satisfied.
(b) Spindle speed synchronous control completion signal (FSPSY)
If the spindle synchronous control command is issued, the FSPSY
signal becomes "1" when both spindles reach the specified
synchronous speed.
Before issuing the spindle phase synchronous control command for
reference position setting, make sure that the synchronous speed
command is "0" and the FSPSY signal is "1".
The signal becomes "1" if the velocity error between the spindles is
smaller than the value specified in parameter No. 4033.