5.CONNECTION OF POWER LINE FANUC AC SERVO MOTOR αiS SERIES B-65262EN/03
- 158 -
CAUTION
1 The motors should be installed with their connector
facing downward as long as possible. When it is
impossible to install a motor in this position, allow slack
in the cable to keep liquids such as a dielectric fluid from
going along the cable into the cable or motor. If there is a
possibility that the motors and connectors get wet,
provide a cover to protect them.
2 When connecting the power line to the terminal block of
a motor, tighten the screw with the following torque:
Terminal size Tightening torque
M4 1.1 N⋅m to 1.5 N⋅m
M5 2.0 N⋅m to 2.5 N⋅m
M6 3.5 N⋅m to 4.5 N⋅m
M8 8.0 N⋅m to 10 N⋅m
M10 15 N⋅m to 16 N⋅m
3 When mounting a crimp terminal at the end of a power
line to keep the insulation distance, always cover the
crimping section of the crimp terminal with an insulating
tube.
When an insulating cover is mounted on the terminal
block, screw the power line, remount the cover in place,
then use the motor.