3.SELECTING A MOTOR SPECIFICATIONS FOR THE αiS/αi SERIES B-65262EN/03
- 74 -
- Positioning distance
Enter the distance as a condition required for calculating the rapid
traverse positioning frequency.
When an exclusive positioning device is used, enter this value
together with the desired positioning time below.
- Required positioning time
Enter the required positioning time when an exclusive positioning
device is used.
When the device is actually attached on the machine tool, note that
servo delay and setting times must also be taken into consideration in
the positioning time.
- In-position set value
Enter the in-position set value as a condition required for calculating
the above positioning times when an exclusive positioning device is
used.
Note that the positioning time changes according to this value.
- Rapid traverse positioning frequency
Enter the rapid traverse positioning frequency by the number of times
per minute.
Enter whether the value is for continuous positioning over a long
period of time or for intermittent positioning within a fixed period of
time. (This value is used to check the OVC alarm and whether the
motor is overheated or not by a flowing current during
acceleration/deceleration, or to check the regenerative capacity of the
amplifier.)