B-63783EN-1/01 11.PROGRAM COMMAND
- 1215 -
#7 #6 #5 #4 #3 #2 #1 #0
6400 SCR
[Input type] Parameter input
[Data type] Bit
# 1 SCR Specifies the unit of magnification used for scaling (G51).
0: 0.00001
1: 0.001
6410 Scaling (G51) magnification
[Input type] Setting input
[Data type] Integer
[Unit of data] Multiplied by 0.001 or 0.00001 depending on the parameter SCR
(No.6400#1).
[Valid data range] 1 - 999999
Set a magnification used for scaling. The value set in this parameter is
used as the default scaling magnification when the scaling
magnification (P) is not specified in the program.
6421 Scaling magnification for each axis
[Input type] Setting input
[Data type] Integeraxis
[Unit of data] Multiplied by 0.001 or 0.00001 depending on the parameter SCR
(No.6400#1).
[Valid data range] 1 - 999999
Set a scaling magnification for each axis.
#7 #6 #5 #4 #3 #2 #1 #0
7611 XSC
[Input type] Setting input
[Data type] Bit
# 4 XSC Specifies whether axis-by-axis scaling magnification setting is valid.
0: Not valid.
1: Valid.
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-14.9 Scaling