11.PROGRAM COMMAND B-63783EN-1/01
- 1236 -
Signals
Lubrication completion signal
OILF<G031#2>
[Classification] Input signal
[Function] After lubrication for hole-making canned cycle is directed by program,
this signal indicates when lubrication is completed.
The signal is used only in type B.
[Operation] The OIL signal is set to "1" simultaneously with the beginning of
operation 3. It is reset to "0" when the OILF signal is received from the
PMC.
The PMC resets the OILF signal to "0" when it detects that the OIL
signal has become "0".
When the OILF signal becomes "0", axis movement in operation 3
begins.
Lubrication signal
OIL<F156#3>
[Classification] Output signal
[Function] This signal indicates that lubrication during hole making canned cycle
has been directed by program.
[Operation] The signal becomes "1" when:
- The program specifies lubrication during hole making canned
cycle.
It becomes "0" when:
- A reset occurs, or
- Type A: The specified time has elapsed since the output of the
OIL signal.
- Type B: The OILF signal becomes "1".
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G31 OILF
F156 OIL
Parameters
#7 #6 #5 #4 #3 #2 #1 #0
6400 OLT OLN
[Input type] Parameter input
[Data type] Bit
# 6
# 6 # 6
# 6 OLN
OLNOLN
OLN Specifies whether to issue the OIL signal.
0: Do not issue.
1: Issue.
NOTE